ECOMax-CT® – Electrolytic CT Water Treatment System

Sustainable Water Treatment Solution

Our Product

Water Treated, Water Saved

ECOMax-CT® – Electrolytic CT Water Treatment System is a chemical free water treatment for cooling towers and it works on the principle of electrolysis of water that reduces upto 80% blow down water consumption.

The process is different from other non chemical water treatment systems and it follows:

The system works in the sidestream of the cooling towers and uses only electricity to treat the circulating water. In the electrolysis process, DC current is passed through the Anode and the Cathode. At the cathode, OH- ions are generated, which creates a high pH environment at the walls of the cathode. This results in the precipitation of calcium and magnesium salts present in the water into the electrolytic reactor. Chlorine gas and other oxidants are generated at the anode, which help reduce bacterial and algae growth in the cooling tower.

Chemical dosing in the cooling towers is drastically reduced/ eliminated. As the scales are removed physically into the electrolytic reactor, it is possible to operate cooling towers at higher levels of TDS/conductivity without the tendency to increase fouling on the heat exchanger surfaces, resulting in a reduction of Cooling Tower blowdown water consumption.

The system has self self-cleaning mechanism to remove deposited scale in the electrolytic reactor online with the help of a scraper and a TDS controller to control the blowdown automatically, thereby maintaining the cooling tower water parameters.

The system also has a sidestream filter to remove suspended solids, and it comes with an auto-backwash facility.

Product Line

Designed for All-Round Efficiency

ECOMax-CT® – Electrolytic CT Water Treatment System has 2 product sub categories that are specifically designed and manufactured for HVAC – Cooling Towers and Power Plant and Process- Cooling Towers

Continuous evaporation of water and Drift Loss causes increase in CT Sump Water TDS resulting into scale formation and High Blow down to maintain circulation water parameters within limits.

Effects

  • Increased Water Wastage
  • High level of Chemical Consumption
  • Replacement of CT Fills periodically
  • Scale is removed from CW water and deposited in the electro-chemical reactor
  • Fully automatic system including reactor cleaning
  • Suitable filter with auto back-wash (optional)
  • Automated blow down from the system
  • No plant shutdown for system installation
  • User-Friendly Graphical User Interface (GUI)
  • Compactness ensures a smaller footprint
  • Low on Maintenance
  • Green Technology

ECOMax CT Icon 01

Zero Chemical Usage by our system

ECOMax CT Icon 02

Reduces blow down water usage up to 80%

ECOMax CT Icon 03

Green Technology

ECOMax CT Icon 04

Reduces Corrosion in Cooling Circuit and Extends life of Cooling Tower

ECOMax CT Icon 05

Saves Energy in case of ZLD plant

ECOMax CT Icon 06

HVAC – Cooling Towers

ECOMax CT Icon 07

Power Plant – Cooling Towers

ECOMax CT Icon 08

Process- Cooling Towers

Contact Us

To get the preliminary pricing information, please drop us an email with following basic information